Figure 11 Engine ON/OFF Switch
ENGINE ON/OFF SWITCH
(GP5000 ENGINES ONLY)
Figure 12 Choke Position
CHOKE LEVER
LEFT = CHOKE (START)
RIGHT = RUN
2.8 STARTING ELECTRIC START ENGINES
Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on.
1 Unplug all electrical loads from the unit's receptacles before starting the engine.
2 Make sure the unit is in a level position (not to exceed 15° in any direction).
3 Open the fuel shut-off valve (Figures 10). 4 Move engine CHOKE lever to FULL CHOKE position (Figure 12).
5 To start engine press and hold the Start/Run/Stop switch (control panel) in the “Start” position The engine will crank and attempt to start When the engine starts release the switch to the run position.
6 When the engine starts move choke knob to “1/2 Choke” position until the engine runs smoothly and then fully in to the
“Run” position If engine falters move choke knob back out to
“1/2 Choke” position until the engine runs smoothly and then to “Run” position.
2.8.1 MANUAL START
This generator is also equipped with a manual recoil starter which may be used if the battery is discharged.
NOTE:
The switch must be in the RUN position Use one of the generator’s receptacle outlets along with the included battery charger to charge the battery while the generator is running.
- To start manually firmly grasp the recoil handle and pull slowly until increased resistance is felt Pull rapidly up and away to start engine Then follow the same choke sequence.
NOTE:
If engine fires but does not continue to run move choke lever to FULL CHOKE and repeat starting instructions IMPORTANT: Do not overload the generator Also do not overload individual panel receptacles These outlets are protected against overload with push-to-reset-type circuit breakers If amperage rating of any circuit breaker is exceeded that breaker opens and electrical output to that receptacle is lost Read “Don’t Overload the
Generator” carefully.
2.9 STOPPING THE ENGINE
1 Shut off all loads then unplug the electrical loads from generator panel receptacles Never start or stop the engine with electrical devices plugged in and turned on.
2 Let engine run at no-load for several minutes to stabilize the internal temperatures of engine and generator.
3 Move Run/Stop switch to OFF position. 4 Close fuel valve.
2.10 LOW OIL LEVEL SHUTDOWN SYSTEM
The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level If the engine shuts down by itself and the fuel tank has enough gasoline check engine oil level.
2.10.1 SENSING LOW OIL LEVEL
If the system senses a low oil level during operation the engine shuts down The engine will not run until the oil has been refilled to the proper level.
Maintenance
Инструкция по эксплуатации Generac GP6000E — страница 13
Инструкция для Инструкция по эксплуатации Generac GP6000E на русском языке. Документ можно использовать для ознакомления с информацией, относящейся к данной модели.
Инструкция представлена в формате PDF, просмотр, скачивание на компьютер, смартфон бесплатно. Возможность печати зависит от используемой программы и настроек устройства. Содержание, структура и объём документа могут различаться в зависимости от модели, версии и редакции руководства. Перед использованием рекомендуется убедиться, что инструкция соответствует вашей модели.